Related Experiment Video
Updated: Aug 18, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Patient self-attenuation and technologist dose in positron emission tomography
Benjamin W Zeff1, Michael V Yester
1Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama 35233, USA. bzeff@uabmc.edu
Abstract:
Positron emission tomography (PET), with 511-keV radiation and long patient-uptake times, presents unique radiation safety concerns. This two-part study considers aspects of PET radiation safety as they relate to PET suite design, dose to the public, and technologist occupational dose. In the first part of the study, the self-attenuation of radiation by patients' bodies was quantified. The radiation exposure was measured at three positions from 64 patients injected with fluorine-18 fluorodeoxyglucose (FDG) during the uptake period. Compared with an in vitro control used as a point source, a significant decrease in exposure (>40% at 1 m) was observed due to nonuniform distribution of FDG and attenuation within the patients. The attenuation data are consistent with results from simulations [M. E. Phelps, "Comments and Perspectives," J. Nucl. Med. 45, 1601 (2004)] that treat the body as a uniform, water-filled cylinder. As distance is often the principal source of protection for 511-keV radiation, the considerable self-attenuation may allow for more compact PET suites. However, despite high patient self-attenuation, shielding, and standard precautionary measures, PET technologist occupational doses can remain quite high (approximately 12 mSv/year). The second part of this study tracked the daily dose received by PET technologists. Close technologist-patient interaction both during and following FDG administration, as much as 20 min/study, contribute to the high doses and point to the need for a more innovative approach to radiation protection for PET technologists.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...