Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using
Songmei Gao1, Zong-Ping Zhang, H T Karnes
1Department of Pharmaceutics, Medical College of Virginia, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA 23298-0533, USA.
Abstract:
High performance liquid chromatography with atmospheric pressure ionization (API) mass spectrometry has been essential to a large number of quantitative analytical applications for a variety of compounds. Poor detection sensitivity however is a problem observed for a number of analytes because detection sensitivity can be affected by many factors. The two most critical factors are the chemical and physical properties of the analyte and the composition of the mobile phase. In order to address these critical factors which may lead to poor sensitivity, either the structure of the analyte must be modified or the mobile phase composition optimized. The introduction of permanently charged moieties or readily ionized species may dramatically improve the ionization efficiency for electrospray ionization (ESI), and thus the sensitivity of detection. Detection sensitivity may also be enhanced via introduction of moieties with high proton affinity or electron affinity. Mobile phase component modification is an alternative way to enhance sensitivity by changing the form of the analytes in solution thereby improving ionization efficiency. pH adjustment and adduct formation have been commonly used to optimize detection conditions. The sensitivity of detection for analytes in bio-matrices could also be enhanced by decreasing ion-suppression from the matrix through derivatization or mobile phase addition. In this review, we will discuss detection-oriented derivatization as well as the application of mobile phase additives to enhance the sensitivity of detection in liquid chromatograph/atmospheric ionization/mass spectrometry (LC/API/MS), focusing in particular on the applications involving small molecules in bio-matrices.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Instrumentation
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...