Related Experiment Video
Updated: Feb 17, 2026

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
The effect of low-flow sevoflurane and desflurane on pulmonary mechanics during laparoscopic surgery
Remziye Sivaci1, Ayse Orman, Mehmet Yilmazer
1Department of Anesthesiology and Re-animation, Kocatepe University, Afyon, Turkey. yasarsivaci@hotmail.com
Background:
This study was designed to investigate the effects of inhaled anesthetic agents on respiratory mechanics with low flow anesthesia in laparoscopic abdominal surgery. Two inhaled anesthetics, desflurane and sevoflurane, have a lower solubility in blood and tissues than all previous volatile anesthetics, and have become the preferred volatile anesthetics for routine surgical procedures.
Methods:
Twenty-six patients were examined. Patients were randomly assigned to two groups, to receive sevoflurane (n = 13) or desflurane (n = 13). Tidal volume and ventilation rate were kept unchanged throughout the operation. Intra-abdominal pressure was kept constant at the level of 12 mm Hg. Respiratory mechanics such as peak inspiratory pressure (PIP), respiratory resistance (Rr), and dynamic compliance (Cdyn) measurements were recorded by a Datex-Ohmeda respiratory device (Datex-Ohmeda, Finland) at four timepoints: 5 minutes after mechanical ventilation started (T1), after insufflation of the peritoneum (T2), in the 30-degree Trendelenburg position (T3), and after desufflation of the peritoneum (T4).
Results:
In our study, desflurane caused a statistically significant increase in PIP and Rr and decrease in C(dyn). When the two groups were compared, Rr values in the deslurane group showed significant increases at T2, T3, and T4 compared to the sevoflurane group (P < 0.05). These values did not change in the sevoflurane group, while PIP significantly increased at T2, T3, and T4 after desufflation in the desflurane group (P < 0.05). Cdyn values decreased significantly at all 4 timepoints in the desflurane group compared to the sevoflurane group (P < 0.05).
Conclusion:
We concluded that respiratory mechanics were affected by desflurane with low flow anesthesia in patients undergoing laparoscopic abdominal surgery. No significant influence on respiratory mechanics was seen with sevoflurane anesthesia.
More Related Videos
Related Concept Videos
Inhalational Anesthetics: Overview
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...