Related Experiment Video
Updated: Aug 18, 2026

Assessment of Dopaminergic Homeostasis in Mice by Use of High-performance Liquid Chromatography Analysis and Synaptosomal Dopamine Uptake
Published on: September 21, 2017
Determination of levodopa methyl ester and its metabolites in rat serum by CZE with amperometric detection
1Department of Chemistry, East China Normal University, Shanghai, 200062, PR China. yuzhi@online.sh.cn
Abstract:
A reliable and reproducible method, capillary zone electrophoresis with amperometric detection (CZE-AD), has been developed for separation and quantification of levodopa methyl ester (LDME) and its biotransformation products levodopa (L-DOPA) and dopamine (DA) in rat serum. A carbon-disk electrode was used as working electrode. The optimum conditions for CZE detection were 50 mmol L(-1) phosphate solution at pH 7.0 as running buffer, 17 kV as separation voltage, 1.0 V (vs Ag/AgCl, 3.0 mol L(-1)) as detection potential, and sample injection for 8 s at 17 kV. The linear ranges were from 2.4 x 10(-2) to 2.2 microg mL(-1) for LDME, 2.9 x 10(-1) to 49.5 microg mL(-1) for L-DOPA, and 1.4 x 10(-2) to 1.5 microg mL(-1) for DA with correlation coefficients of 0.9997, 0.9994, and 0.9999, respectively. The detection limits for LDME, L-DOPA, and DA were 14.6, 98.0, and 9.7 ng mL(-1), respectively. Recoveries were 80.3% for LDME, 93.5% for L-DOPA, and 86.5% for DA. This method was applied to serum samples after intravenous injection of LDME and L-DOPA to rats.