[Polished stem displacement from a cement mantle--a case report]

Jan Blacha1

  • 1Katedra i Klinika Ortopedii, Traumlatologii i Rehabilitacji, Akademia Medyczna w Lublinie.

Chirurgia Narzadow Ruchu I Ortopedia Polska
|May 26, 2005
PubMed
Summary

Dislocation after hip arthroplasty can lead to complications. A rare case of polished Exeter stem displacement during closed reduction highlights the need for specific cementing techniques to prevent revision surgery.