Pharmacist detection of peripheral arterial disease through the use of a handheld Doppler
Kristin Zerumsky1, Karen L Steinmetz, Steven M Handler
1Department of Pharmacy and Therapeutics, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
Study Objective:
To evaluate the effectiveness of a program in which pharmacists screened at-risk patients for peripheral arterial disease using a handheld doppler device.
Design:
Prospective study.
Setting:
Primary care and consultative outpatient clinic.
Patients:
Forty-one physician-referred patients older than 55 years who had no documented history of peripheral arterial disease.
Intervention:
The pharmacists administered the San Diego Claudication Questionnaire and performed doppler examinations to calculate ankle-to-brachial indexes (ABIs). Patients with symptoms of claudication or with an ABI of 0.9 or less were considered to have possible peripheral arterial disease. Each diagnosis was confirmed by a physician. These patients were either referred for further evaluation, provided with immediate treatment, or told to continue their current drug regimen, if appropriate.
Measurements And Main Results:
Eight (19.5%) of the 41 patients were diagnosed with peripheral arterial disease. Antiplatelet therapy was started in five patients, and one patient was referred to a vascular specialist.
Conclusion:
This pharmacist-initiated program effectively detected peripheral arterial disease in previously unscreened patients.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Peripheral Artery Disease I: Introduction
Pulse
The pulse serves as a clinical indicator...
Pulse Assessment Sites