Related Experiment Video
Updated: Jan 20, 2026

Use of an Influenza Antigen Microarray to Measure the Breadth of Serum Antibodies Across Virus Subtypes
Published on: July 26, 2019
Simultaneous measurement of specific serum IgG responses to five select agents
R E Biagini1, D L Sammons, J P Smith
1Biomonitoring and Health Assessment Branch, Division of Applied Research and Technology, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, Cincinnati, OH 45226, USA. reb4@cdc.gov
Abstract:
Select Agents are defined by CDC and the USDA Animal and Plant Health Inspection Service (APHIS) as biological agents or toxins deemed a threat to public, animal, or plant health, or to animal or plant products. They are classified on the basis of their ease of dissemination, mortality/morbidity rate, and potential for social disruption. A subset of these agents includes Bacillus anthracis, Yersinia pestis, Francisella tularensis, ricin toxin (RT), and staphylococcal enterotoxin B (SEB). Infection or intoxication with these agents has been shown to elicit an antigen-specific serum IgG response. We describe a fluorescent covalent microsphere immunoassay (FCMIA) for measurement of specific IgG antibodies to seven different antigens from five different select agents; B. anthracis [protective antigen (PA) and lethal factor (LF)], Y. pestis (F1 and V antigens), F. tularensis, RT and SEB simultaneously in human B. anthracis vaccinee sera (containing anti-PA and anti-LF IgG) which had been spiked with animal specific IgG antibodies to the other select agents. Inter-assay and intra-assay coefficients of variation were 6.5 and 13.4%, respectively (N = 4). There were no significant differences (P > 0.70) between assay responses when the assays were performed individually or multiplexed. When the observed versus expected interpolated concentrations were compared, highly linear relationships were observed (r2 values from 0.981 to 0.999, P < 0.001). Minimum detectable concentrations (MDC) ranged from 0.3 ng mL(-1) (Y. pestis F1) to 300 ng mL(-1) (RT). Finally, the curves showed responses were linear for most analytes from their MDC to 125 (SEB) to 1,300 (Y. pestis F1) x their MDC. These data indicate that multiplexed FCMIA is a sensitive and accurate method for simultaneous measurement of specific IgG in serum to CDC select agents and may be of value in screening either decontamination workers or the general population for exposure to/infection with these agents.
Related Concept Videos
08:52Use of an Influenza Antigen Microarray to Measure the Breadth of Serum Antibodies Across Virus Subtypes
07:10Direct Intrabronchial Administration to Improve the Selective Agent Deposition Within the Mouse Lung
09:12A Protein Microarray Assay for Serological Determination of Antigen-specific Antibody Responses Following Clostridium difficile Infection
10:16Generation of Two-color Antigen Microarrays for the Simultaneous Detection of IgG and IgM Autoantibodies
Dose-Response Relationship: Selectivity and Specificity
04:51Measuring Immunoglobulin G Levels Against a Test Vaccine in a Mouse Serum