Related Experiment Video
Updated: Aug 17, 2026

Voltage-Dependent Potassium Current Recording on H9c2 Cardiomyocytes via the Whole-Cell Patch-Clamp Technique
Published on: November 11, 2022
Estimation of potency of HERG channel blockers: impact of voltage protocol and temperature
Jian-An Yao1, Xiaoyi Du, Daniel Lu
1Department of Safety Pharmacology, Quintiles, Kansas City, MO 64137, USA. jianan.yao@quintiles.com
Introduction:
The HERG channel is widely used for the assessment of proarrhythmic risk for new drugs. HERG channel blockers obstruct channel functions through various mechanisms, which usually show time dependence, voltage dependence, and state dependence. The voltage protocol and temperature may affect the estimation of drug potency, but limited information is available in this regard. The purpose of this study was to evaluate the influence of voltage protocol and temperature on predicting the potency of HERG channel blockers, and to determine electrophysiological approaches for new drugs screening studies.
Method:
Whole-cell patch-clamp electrophysiology was carried out by utilizing different voltage step protocols to examine the potency of compounds known to preferentially block the channel in the closed (ketoconazole and BeKm-1), open, and/or inactivated states (E-4031, astemizole, and terfenadine) in HEK293 cells transfected with HERG cDNA at room temperature and near-physiological temperature.
Results:
Drug potency determined using different voltage protocols varied dependent on the mechanisms of drug actions. For most compounds, the IC(50) values obtained with a long pulse step protocol at room temperature were close to those determined with the voltage protocols designed to disclose their intrinsic potency. Relative to room temperature, the potency of E-4031, terfenadine, and ketoconazole was not changed at approximately 35 degrees C, but potency of astemizole was reduced.
Discussion:
The long pulse step protocol with room temperature can be selected for HERG channel safety screening studies. Alternative voltage protocols or temperatures should be considered if HERG study results are not consistent with other cardiac safety assessments.
Related Concept Videos
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Depolarizing Blockers: Pharmocokinetics
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Dose-Response Relationship: Potency and Efficacy