Intercellular conduction velocity variability as the basis for re-entrant arrhythmias in the ischemic myocardium
Related Experiment Video
Updated: Nov 8, 2026

Isolation and Functional Characterization of Human Ventricular Cardiomyocytes from Fresh Surgical Samples
Published on: April 21, 2014
1Rappaport Family Institute for Research in the Medical Sciences, Technion-Israel Institute of Technology, Haifa.
Abstract:
Re-entrant arrhythmias are the major cause of death from cardiovascular disease. A number of models or mechanisms have been proposed to explain the generation of re-entrant arrhythmias in the ischemic or damaged heart. However, none of these models can qualitatively predict the formation of re-entry movements with no modifications of the basic electrophysiologic characteristics of the myocardium. In this presentation we evaluate the concept that the generation of re-entrant arrhythmias is due to increased variance in the conduction characteristics of the cardiac tissue, rather than to modification of these properties. Using a model of a homogeneous two-dimensional matrix of excitable conducting cells, we derived the relationship between the relative standard deviation (RSD) and the probability of occurrence of a local ordered dispersion of velocities shown to have the potential to result in circular propagation. This probability was found to be insignificant when the RSD was lower than 10%, but increased dramatically for RSDs greater than 10%. On the basis of experimental RSD, the calculated probability for circus movement formation is one in 10,000 normal heart beats and one in two ischemic heart beats. The model provides new insight into the mechanism of re-entrant arrhythmias as well as new tools for diagnosis.
More Related Videos
06:40Impact of Intracardiac Neurons on Cardiac Electrophysiology and Arrhythmogenesis in an Ex Vivo Langendorff System
Published on: May 22, 2018
09:35Preclinical Cardiac Electrophysiology Assessment by Dual Voltage and Calcium Optical Mapping of Human Organotypic Cardiac Slices
Published on: June 16, 2020
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Dysrhythmias III: Characteristics of Dysrhythmias