Related Experiment Video
Updated: Aug 17, 2026

Detection of CD40 Protein-Umbelliferone Interaction via Differential Scanning Fluorescence
Published on: March 1, 2024
Direct optical detection of protein-ligand interactions
Frank Gesellchen1, Bastian Zimmermann, Friedrich W Herberg
1Department of Biochemistry, University of Kassel, Kassel, Germany.
Abstract:
Direct optical detection provides an excellent means to investigate interactions of molecules in biological systems. The dynamic equilibria inherent to these systems can be described in greater detail by recording the kinetics of a biomolecular interaction. Optical biosensors allow direct detection of interaction patterns without the need for labeling. An overview covering several commercially available biosensors is given, with a focus on instruments based on surface plasmon resonance (SPR) and reflectometric interference spectroscopy (RIFS). Potential assay formats and experimental design, appropriate controls, and calibration procedures, especially when handling low molecular weight substances, are discussed. The single steps of an interaction analysis combined with practical tips for evaluation, data processing, and interpretation of kinetic data are described in detail. In a practical example, a step-by-step procedure for the analysis of a low molecular weight compound interaction with serum protein, determined on a commercial SPR sensor, is presented.
Related Concept Videos
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...