Related Experiment Video
Updated: Aug 14, 2026

Multiscale Sampling of a Heterogeneous Water/Metal Catalyst Interface using Density Functional Theory and Force-Field Molecular Dynamics
Published on: April 12, 2019
Rosenbluth-sampled nonequilibrium work method for calculation of free energies in molecular simulation
1Department of Chemical and Biological Engineering, University at Buffalo, The State University of New York, Buffalo, New York 14260-4200, USA.
Abstract:
We present methods that introduce concepts from Rosenbluth sampling [M. N. Rosenbluth and A. W. Rosenbluth, J. Chem. Phys. 23, 356 (1955)] into the Jarzynski nonequilibrium work (NEW) free-energy calculation technique [C. Jarzynski, Phys. Rev. Lett. 78, 2690 (1997)]. The proposed hybrid modifies the way steps are taken in the NEW process. With it, each step is selected from a range of alternatives, with bias given to steps that contribute the least work. The definition of the work average is modified to account for the bias. We introduce two variants of this method, lambda-bias sampling and configuration-bias sampling, respectively; a combined lambda- and configuration-bias method is also considered. By reducing the likelihood that large nonequilibrated work values enter the ensemble average, the Rosenbluth sampling aids in remedying problems of inaccuracy of the calculation. We demonstrate the performance of the proposed methods through a model system of N independent harmonic oscillators. This model captures the difficulties involved in calculating free energies in real systems while retaining many tractable features that are helpful to the study. We examine four variants of this model that differ qualitatively in the nature of their phase-space overlap. Results indicate that the lambda-bias sampling method is most useful for systems with entropic sampling barriers, while the configuration-bias methods are best for systems with energetic sampling barriers. The Rosenbluth-sampling schemes yield much more accurate results than the unbiased nonequilibrium work method. Typically the accuracy can be improved by about an order of magnitude for a given amount of sampling; this improvement translates into two or more orders of magnitude less sampling required to obtain a given level of accuracy, owing to the generally slow convergence of the NEW calculation when the inaccuracy is large.
Related Concept Videos
Gibbs Free Energy
Calculating Standard Free Energy Changes
Free Energy and Equilibrium
Recall that Q is the numerical value of the mass action expression...
The Nernst Equation
The interconnection between standard cell potentials and various thermodynamic parameters such as the standard free energy change ΔG° and equilibrium constant K has been previously explored. For example, a redox reaction involving zinc(II) and tin(II) ions at 1 M concentration with Eºcell = +0.291 V and ΔG° = −56.2 kJ is spontaneous.
An Introduction to Free Energy
Free Energy and Equilibrium
The reaction quotient, Q, is a convenient measure of the status of an...

