Related Experiment Video
Updated: Aug 17, 2026

Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
Pneumatic pulsatile ventricular assist devices in children under 1 year of age
Brigitte Stiller1, Yuguo Weng, Michael Hübler
1Department of Pediatric Cardiology, Deutsches Herzzentrum Berlin, 13353 Berlin, Germany. stiller@dhzb.de
Objective:
Although considerable progress has been made on ventricular assist devices (VAD) for adults, pneumatic pulsatile circulatory support in young infants is still limited. There is a need for long-term ventricular assist devices to bridge the failing myocardium of young children until recovery or transplantation. Miniaturized devices and innovative modalities need to be optimized. We report on our experience.
Methods:
From 1/1992 to 6/2004, 18 infants (6 male/12 female) under 1 year of age were treated with the Berlin Heart Excor VAD. The infants were divided into two groups, depending on the year of treatment. Group A consists of eight infants resuscitated and supported with a pulsatile pneumatic ventricular assist device between 1992 and 1998 and group B consists of 10 infants treated between 1999 and 6/2004. With the pediatric-sized Berlin Heart we used miniaturized extracorporeal pneumatically driven blood pumps, the lowest stroke volume being 10 ml.
Results:
In 18 children, age 3-345 (median 147) days, artificial replacement of heart function was applied for long-term support (1-64, median 10 days) as a life-saving measure in our hospital. Nine had LVAD and nine BVAD support. All were in cardiogenic shock with multiorgan failure; three had fulminant myocarditis, four cardiomyopathy, and one chronic stage of congenital heart disease. Five children were weaned from the system, three reached heart transplantation, and 10 died on the VAD. There were no differences between groups A and B regarding age, body weight or diagnosis, but the duration of mechanical support differed: Group A, median 2, range 1-16 days; group B, median 12, range 1-100 days. Since 1999 (group B), the survival rate of our small infants has increased to 70% whereas none of the infants in group A survived to be discharged.
Conclusions:
The outcome of VAD support in small infants is no longer inferior to that of adult support, now optimized cannulas, modified anticoagulation and optimized surgical and intensive care management have been established.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
Cardiopulmonary Resuscitation II: ACLS Airway Management