Mixed venous oxygen desaturation during early mobilization after coronary artery bypass surgery
I Kirkeby-Garstad1, O F M Sellevold, R Stenseth
1Department of Anesthesia and Intensive Care, St Olav Hospital, University Hospital of Trondheim, Trondheim, Norway. Idar.Kirkeby-Garstad@medisin.ntnu.no
Background:
Early postoperative mobilization induces a marked reduction in mixed venous oxygen saturation (S(v)O(2)) after aortic valve replacement. We investigated whether a similar desaturation occurs among coronary artery bypass grafting (CABG) patients, and if the desaturation was related to the preoperative ejection fraction (EF).
Methods:
Thirty-one CABG patients with a wide range in EF were included in an open observational study. We recorded hemodynamic and oxygenation variables during mobilization on postoperative day 1 and day 2 using a pulmonary artery catheter.
Results:
Patients with an EF ranging from 24 to 87% were mobilized without clinical problems. S(v)O(2) at rest was 65.4 +/- 4.9% (mean +/- SD) on day 1 and 64.3 +/- 5.8% on day 2 (NS). During mobilization, cardiac index and oxygen delivery were reduced while oxygen consumption was increased (P-values: 0.000, 0.007 and 0.000, respectively). Consequently, oxygen extraction increased, resulting in a marked reduction in S(v)O(2)-42.9 +/- 8.3% on day 1 and 47.4 +/- 8.5% on day 2 (P = 0.025 between days). Several pre-, intra- and postoperative factors were tested as possible predictors for S(v)O(2) during mobilization. No factor contributed substantially.
Conclusion:
Patients with CABG exhibit a marked desaturation during early postoperative mobilization. Preoperative ejection fraction did not affect S(v)O(2) during exercise. The clinical consequences and underlying mechanism require further investigation.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood
Peripheral Artery Disease V: Postoperative Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Acute Coronary Syndrome V: Nursing Management