Related Experiment Video
Updated: Aug 17, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Mechanical properties of gamma irradiated morselized bone during compaction
Adam M Butler1, David A F Morgan, Richard Verheul
1Orthopaedic Research Laboratories, University of New South Wales, Prince of Wales Hospital, Sydney, Australia.
Abstract:
This study examined the effects of gamma irradiation on the compressive properties of morselized cancellous bone from human femoral heads. Twelve bone samples, mean age of 68 years (range 92-39), were divided into 3 groups (N=12) of varying irradiation level (0, 15 and 25 kGy). Each specimen was compacted in a controlled fashion in steps of 0.5 mm at 0.5 mm/min (up 12 mm). The load and stiffness increased with compaction, but this relationship was not linear. There was no statistical significant difference in the compacting load or stiffness between groups (p>0.05) until the last 1 mm of compaction, where the 25 kGy group were significantly stiffer compared to controls but not different to the 15 kGy group. This may be due to decreased interlocking of bone particles caused by higher irradiation levels resulting in a stiffer graft.
Related Concept Videos
Mortar Properties
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...