Related Experiment Video
Updated: Jul 16, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Quantitative measurements of NO reaction kinetics with a Clark-type electrode
Xiaoping Liu1, Qihui Liu, Era Gupta
1Davis Heart and Lung Research Institute and Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University, Columbus, OH 43210, USA. liu-11@medctr.osu.edu
Abstract:
Nitric oxide (NO) plays important physiological roles in the body. Knowledge regarding the kinetics of NO catabolism is important for understanding the biological functions of NO. Clark-type NO electrodes have been frequently employed in measuring the kinetics of NO reactions; however, the slow response time of these electrodes can cause measurement errors and limit the application of the electrode in measurements of fast NO reactions. In this study, a simplified diffusion model is given for describing the response process of the NO electrode to the change of NO concentration. The least-square method is used in fitting the currents calculated from the diffusion equation to the experimental curves for determining the diffusion parameters and rate constants. The calculated currents are in excellent accordance with the experimental curves for different NO reaction kinetics. It has been demonstrated that when using an NO electrode with a response time of approximately 6 s to measure fast NO reactions with a half-life of approximately 1s, the response currents of the electrode have large differences compared to the curve of actual NO concentration in the solution; however, the rate constant of NO decay can still be accurately determined by computer simulations with the simplified diffusion model. Theoretical analysis shows that an NO electrode with a response time of 6 s (D/L2=0.06 s-1) and the lowest detection limit of 1 nM NO can be used in measuring kinetics of extremely rapid NO reactions with a half-life below 10 ms.
Related Concept Videos
Measuring Reaction Rates
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Electrodeposition
Electrodeposition can...
Controlled-Current Coulometry: Overview