Related Experiment Video
Updated: Aug 17, 2026

Patch Angioplasty in the Rat Aorta or Inferior Vena Cava
Published on: February 27, 2017
Pericardial patch augmentation for reconstruction of incompetent bicuspid aortic valves
Mirko Doss1, Reinhard Moid, Jeffrey Paul Wood
1Department of Thoracic and Cardiovascular Surgery, J. W. Goethe University, Frankfurt am Main, Germany. mirkodoss@aol.com
Purpose:
Reoperation rates after repair of bicuspid aortic valves are higher than for mitral valve reconstruction. Secondary changes and small coaptation surface render repair unreliable. Satisfactory results have been reported for patch augmentation for tricuspid aortic valves. We have applied this technique for the repair of bicuspid aortic valves.
Description:
Our technique retains the bicuspid morphology of the incompetent aortic valve. A strip of glutaraldehyde-fixed pericardium is sutured to the free edge of the fused leaflet. A large coaptation surface is created, and competence of the bicuspid valve is achieved.
Evaluation:
Sixteen patients underwent reconstruction of their bicuspid aortic valves by pericardial patch augmentation. There were no intraoperative or postoperative deaths. The degree of aortic regurgitation was none to trivial for all patients at a mean follow-up of 3.1 +/- 3.4 months. Planimetric effective orifice areas ranged above 2 cm2. Mean aortic gradients were 8.2 +/- 4.8 mm Hg, and the mean height of coaptation surface was 14.7 +/- 2.1 mm.
Conclusions:
The pericardial patch augmentation technique increases coaptation surface, and thus provides reliable early competence of reconstructed bicuspid aortic valves.
More Related Videos
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery (ALCAPA)
Published on: April 24, 2017
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement