Effects of external pressure on arteries distal to the cuff during sphygmomanometry
Meir Nitzan1, Chaim Rosenfeld, A Teddy Weiss
1Department of Physics/Electro-Optics, Jerusalem College of Technology, P.O. Box 16031, Jerusalem 91160, Israel. nitzan@jct.ac.il
Abstract:
The aim of this study was to examine the effect on distal arteries of external pressure, applied by upper arm sphygmomanometer cuff. Photoplethysmographic (PPG) signals were measured on the index fingers of 44 healthy male subjects, during the slow decrease of cuff air pressure. For each pulse the ratio of PPG amplitude to its baseline (AM/BL) and its time delay (deltaTD) relative to the contralateral hand were determined as a function of cuff pressure. At cuff pressures equal to systolic blood pressure, pulses reappeared with the pulse time delay in the cuffed arm significantly greater than in the noncuffed arm, with (deltaTD) (mean +/- SD) 150 +/- 31 ms (p < 0.001). At cuff pressures equal to diastolic blood pressure (81 +/- 12 mmHg), deltaTD was 42 +/- 19 ms (p < 0.001), and at 50 mmHg, which is below diastolic blood pressure, (deltaTD) was still significantly positive at 6 +/- 9 ms (p < 0.001). AM/BL relative to its initial value rose at cuff pressures between systolic and diastolic blood pressure, then deceased to 0.6 +/- 0.41 (p < 0.001) at diastolic blood pressure and 0.54 +/- 0.24 (p < 0.001) at 50 mmHg. The changes in (deltaTD) and AM/BL can be interpreted as originating from changes in the compliance of conduit arteries and small arteries with cuff inflation and deflation.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...