Related Experiment Video
Updated: Aug 17, 2026

Combination of Microstereolithography and Electrospinning to Produce Membranes Equipped with Niches for Corneal Regeneration
Published on: September 12, 2014
Management of pellucid marginal degeneration with intracorneal ring segments
Adel Barbara1, Raneen Shehadeh-Masha'our, Friedman Zvi
1Hadassa Optimal, Israel.
Purpose:
To present intracorneal ring segments for potential management of pellucid marginal degeneration.
Methods:
A 41-year-old man with pellucid marginal degeneration with poor visual acuity due to irregular astigmatism was treated with Intacs microthin insert (KeraVision, Fremont, Calif) in the left eye.
Results:
Uncorrected visual acuity improved from 2/60 to 6/60 following the procedure. The procedure completely eliminated myopia of -8.00 diopters and improved the irregularity of the astigmatism, although it did not change its magnitude.
Conclusions:
Insertion of the intracorneal ring segment improves visual acuity in pellucid marginal degeneration by flattening the central corneal protrusion, thus reducing myopia and improving the astigmatism irregularity.