Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Focal beam distortion and treatment planning in abdominal focused ultrasound surgery
Hao-Li Liu1, Nathan McDannold, Kullervo Hynynen
1Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, 02115, USA. haoliliu@mail.cgu.edu.tw
Abstract:
Recent clinical trials show promising results in using MRI and MRI-based thermometry to guide focused ultrasound surgery to treat uterine fibroids. During treatment, large variation in the focal temperature distribution has been observed. It is possible that some of this variation is due to abdominal tissue inhomogeneity, which might be causing focal beam distortion, and might largely decrease the focusing ability in deep-seated tissues. The purpose of this study was to numerically demonstrate this effect and also show the feasibility of restoring the focal beam patterns by employing the phase correction procedure for phased arrays. Abdominal MR data from four uterine fibroid patients were obtained to reconstruct the three-dimensional meshes of interfaces used in simulations, and one patient was selected to perform the analysis of key parameters in focused ultrasound surgery. Results show that, without phase correction, the focused beam can be severely distorted while using a frequency above 1 MHz or delivering ring-shape focal patterns. Different focal positions at the same depth may require a different power to induce the same ultrasonic intensity level (up to 179% among the different focal patterns). After adding a phase correction procedure, the distorted focal beams can be restored, and the peak intensity can be largely recovered (up to 85% among the different focal patterns). This study may offer important implications and information for treatment planning toward optimizing focused ultrasound surgery in uterine fibroid or other abdominal tumor treatments.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU)
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...