The Preparation of Electrohydrodynamic Bridges from Polar Dielectric Liquids
Published on: September 30, 2014
Transient electrophoresis of dielectric spheres
1Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan, Republic of China. huan@ntu.edu.tw
Abstract:
The dynamic electrophoretic response of a spherical dielectric particle suspended in an electrolyte solution to a step change in the applied electrics field is analytically studied. The electrical double layer surrounding the particle may have either a small but finite thickness or a very large thickness relative to the particle radius. For the case of electrophoresis of a particle with a thin double layer, the local electroosmotic velocity at the outer edge of the double layer evolving with time after the external field is imposed is used as an apparent slip boundary condition at the particle surface so that the unsteady equation of motion for the fluid flow outside the double layer is solved. Closed-form formulas for the transient electrophoretic mobility of the particle are derived as functions of relevant parameters. The results demonstrate that, when the double layer surrounding the particle is relatively thin, the normalized electrophoretic mobility at a given dimensionless time decreases monotonically with a decrease in the parameter kappaa, where kappa(-1) is the Debye screening length and a is the particle radius. When the double layer of the particle is relatively thick, the particle mobility can have magnitudes comparable to those for a particle with a thin double layer in the initial stage, but will become much smaller afterward. In general, the effect of the relaxation time for transient electrophoresis is negligible, regardless of the value of kappaa.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Capillary Electrophoresis: Instrumentation
Electric Field of a Non Uniformly Charged Sphere
Consider a non-uniformly charged sphere, for which the density of charge depends only on the distance from a point in space and not on the direction. Such a sphere has a spherically symmetrical charge distribution. Here, the electric...