Related Experiment Video
Updated: Aug 17, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Static thermography revisited--an adjunct method for determining the depth of the burn injury
Alicja Renkielska1, Antoni Nowakowski, Mariusz Kaczmarek
1Department of Plastic Surgery and Burns, Medical University of Gdansk, ul. Debinki 7, 80 211 Gdansk, Poland. aren@mlyniec.gda.pl
Abstract:
The aim of the study was to investigate the relationship between the static thermography figure of merit DeltaT (the difference in mean values of skin area temperature for the burn wound area and the unaffected reference skin area) and a means of burn classification which would be most suitable for the choice of treatment. The work was an in vivo animal experiment. Statistical analysis showed a high correlation between the DeltaT parameter and histopathological assessment. With regard to the choice of treatment, the most useful correlation was found to be that between DeltaT and the classification of burn wounds into those healed in 3 weeks and those unhealed. The results of this study have revealed a quantitative criterion DeltaT for burn classification. The study suggests that particular burn centres using static thermography use a DeltaT parameter based on their own values for burn classification so as to group burn wounds into those that healed in 3 weeks and those that did not heal. This criterion should be independent of and replace other classification systems. A criterion for the proper choice of burn treatment would then be made more readily available.
Related Concept Videos
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Flame Photometry: Overview
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...