Related Experiment Video
Updated: Aug 17, 2026

Identification and Quantification of Deranged Metabolites in Critically Ill Patients Using NMR-Based Metabolomics
Published on: November 29, 2024
A study of spectral integration and normalization in NMR-based metabonomic analyses
Bobbie-Jo M Webb-Robertson1, David F Lowry, Kristin H Jarman
1Pacific Northwest National Laboratory, P.O. Box 999, K7-90, Richland, WA 99352, USA. bobbie-jo.webb-robertson@pnl.gov
Abstract:
Metabonomics involves the quantitation of the dynamic multivariate metabolic response of an organism to a pathological event or genetic modification [J.K. Nicholson, J.C. Lindon, E. Holmes, Xenobiotica 29 (1999) 1181-1189]. The analysis of these data involves the use of appropriate multivariate statistical methods; Principal Component Analysis (PCA) has been documented as a valuable pattern recognition technique for 1H NMR spectral data [J.T. Brindle, H. Antti, E. Holmes, G. Tranter, J.K. Nicholson, H.W. Bethell, S. Clarke, P.M. Schofield, E. McKilligin, D.E. Mosedale, D.J. Grainger, Nat. Med. 8 (2002) 1439-1444; B.C. Potts, A.J. Deese, G.J. Stevens, M.D. Reily, D.G. Robertson, J. Theiss, J. Pharm. Biomed. Anal. 26 (2001) 463-476; D.G. Robertson, M.D. Reily, R.E. Sigler, D.F. Wells, D.A. Paterson, T.K. Braden, Toxicol. Sci. 57 (2000) 326-337; L.C. Robosky, D.G. Robertson, J.D. Baker, S. Rane, M.D. Reily, Comb. Chem. High Throughput Screen. 5 (2002) 651-662]. Prior to PCA the raw data is typically processed through four steps; (1) baseline correction, (2) endogenous peak removal, (3) integration over spectral regions to reduce the number of variables, and (4) normalization. The effect of the size of spectral integration regions and normalization has not been well studied. The variability structure and classification accuracy on two distinctly different datasets are assessed via PCA and a leave-one-out cross-validation approach under two normalization approaches and an array of spectral integration regions. The first dataset consists of urine from 15 male Wistar-Hannover rats dosed with ANIT measured at five time points, mimicking drug-induced cholangiolitic hepatitis [D.G. Robertson, M.D. Reily, R.E. Sigler, D.F. Wells, D.A. Paterson, T.K. Braden, Toxicol. Sci. 57 (2000) 326-337; J.P. Shockcor, E. Holmes, Curr. Top. Med. Chem. 2 (2002) 35-51; N.J. Waters, E. Holmes, A. Williams, C.J. Waterfield, R.D. Farrant, J.K. Nicholson, Chem. Res. Toxicol. 14 (2001) 1401-1412]. The second data is serum samples from young male C57BL/6 mice subjected to instillation of pancreatic elastase producing emphysema type symptoms [C. Kuhn, S.Y. Yu, M. Chraplyvy, H.E. Linder, R.M. Senior, Lab. Invest. 34 (1976) 372-380; C. Kuhn, R.M. Senior, Lung 155 (1978) 185-197]. This study indicates that independent of the normalization method the classification accuracy achieved from metabonomic studies is not highly sensitive to the size of the spectral integration region. Additionally, both datasets scaled to mean zero and unity variance (auto-scaled) have higher variability within classification accuracy over spectral integration window widths than data scaled to the total intensity of the spectrum. Of the top 10 latent variables for the ANIT dataset the auto-scale normalization has standard deviations larger than the total-scale in seven cases. In the case of the elastase all standard deviations are larger for the auto-scaling.
More Related Videos
07:54Assessing Hepatic Metabolic Changes During Progressive Colonization of Germ-free Mouse by 1H NMR Spectroscopy
Published on: December 15, 2011
11:47Concentration of Metabolites from Low-density Planktonic Communities for Environmental Metabolomics using Nuclear Magnetic Resonance Spectroscopy
Published on: April 7, 2012
Related Concept Videos
¹H NMR Signal Integration: Overview
Applications Of NMR In Biology
The...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
NMR Spectrometers: Overview
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...