Exposure to indoor allergens in day-care facilities: results from 2 North Carolina counties
Samuel J Arbes1, Michelle Sever, Jigna Mehta
1Division of Intramural Research, National Institute of Environmental Health Sciences, National Institutes of Health, MD, USA.
Insights
Day-care facilities commonly contain indoor allergens like Alternaria alternata and Can f 1. These facilities may expose young children and staff to clinically relevant levels of allergens.
Area of Science:
- Environmental Health
- Allergen Exposure
- Pediatric Health
Background:
- Day-care facilities are common for children under 5.
- These settings may be significant sources of indoor allergen exposure.
Purpose of the Study:
- To assess levels of 7 indoor allergens in North Carolina day-care facilities.
- To compare allergen levels with those found in US homes.
Main Methods:
- Dust samples collected from 89 day-care facilities.
- Allergen concentrations measured using ELISAs.
- Questionnaires and observations also conducted.
Main Results:
- All 7 allergens detected in most facilities (52-100%).
- Carpeted areas showed higher levels of 5 allergens (A. alternata, Can f 1, Der f 1, Der p 1, Fel d 1).
- Allergen levels were comparable to those in southern US homes.
Conclusions:
- Detectable indoor allergens are prevalent in North Carolina day-care centers.
- Day-care facilities may pose a risk for allergen exposure to children and staff.
Background:
With 63% of US children under 5 years of age in regular child care, day-care facilities could be an important source of exposure to indoor allergens.
Objective:
This study examined levels of 7 indoor allergens in 89 day-care facilities in 2 North Carolina counties.
Methods:
At each facility, a questionnaire was administered, observations were made, and vacuumed dust samples were collected from carpeted and noncarpeted areas of one room. Allergen concentrations were measured with antibody-based ELISAs.
Results:
Each allergen was detected in a majority of facilities (52% to 100%). Geometric mean concentrations were 5.19 mug/g for Alternaria alternata , 2.06 mug/g for Can f 1, 1.43 microg/g for Fel d 1, 0.21 U/g for Bla g 1, 0.20 microg/g for Der p 1, 0.10 microg/g for Der f 1, and 0.01 microg/g for Mus m 1. Concentrations for 5 of the 7 allergens were not statistically different from concentrations found in southern US homes sampled in the National Survey of Lead and Allergens in Housing. In rooms with carpet and hard-surfaced flooring, levels of A alternata , Can f 1, Der f 1, Der p 1, and Fel d 1 were statistically higher on carpet.
Conclusions:
In this survey of day-care facilities in North Carolina, detectable levels of indoor allergens were commonly found. For many young children and day-care staff, day-care facilities might be a source of clinically relevant exposures to indoor allergens.
More Related Videos
Related Concept Videos
Allergic Reactions
Specialized Care Centers and Settings-II
Rural health centers are specialized care facilities in remote locations with very few medical personnel. The primary care providers who run the centers are mostly Registered Nurse Practitioners. Here, emergency treatment is provided to critically ill or injured patients before they are transferred to the closest hospital. Fortunately, due to advancement in technology, many rural healthcare facilities and professionals have easy access to diagnostic and treatment...
Antiasthma Drugs: Mast Cell Stabilizers and Anti-IgE Drugs
Mast cell stabilizers, such as cromolyn (also known as sodium cromoglycate) and nedocromil (Tilade), are effective drugs in asthma management. These stabilizers hinder histamine release by skillfully obstructing the activation of mast cells and other cellular entities. Notably, they navigate this task without...
Asthma-I: Introduction
Allergic Reactions: Anaphylaxis
Asthma I: Introduction