Related Experiment Video
Updated: Aug 17, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Intracoronary brachytherapy for in-stent restenosis using long sources reduces restenosis
Ramanjit Bagga1, Annapoorna Kini, Paul Lee
1Department of Interventional Cardiology, Mount Sinai Medical Center, One Gustave Levy Place, Box 1030, New York, NY 10029, USA.
Abstract:
Edge restenosis (candy wrapper effect) and late thrombosis remain a problem in various randomized intracoronary brachytherapy (ICBT) trials for the treatment of in-stent restenosis (ISR). Target vessel revascularization (TVR) due to target lesion revascularization (TLR) and edge restenosis can be decreased with the use of longer ICBT sources and debulking devices and has not been systematically studied. We analyzed 226 patients with ISR (240 vessels of 264 lesions; average lesion length 17.5+/-8.9 mm) who had lesion debulking followed by 90 Strontium (Sr) beta-irradiation using the Novoste Betacath system (30 mm source in 144 vessels and 40 mm source in 96 vessels). Dual antiplatelet therapy was recommended for one year. At follow-up of 12+/-2 months, clinical TVR occurred in 9.7%, with TLR in 7.1% and non-TLR in 2.6% of cases. There was no delayed or late subacute thrombosis. Beta-irradiation using a longer 90Sr source after lesion modification with cutting balloon (CB) and or rotational atherectomy (RA), along with the use of long-term dual antiplatelet therapy is safe and associated with single-digit clinical restenosis.