Related Experiment Video
Updated: Aug 17, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Tumor lesion detection: when is integrated positron emission tomography/computed tomography more accurate than
Ur Metser1, Orit Golan, Charles D Levine
1Department of Nuclear Medicine, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel. umetser@tasmc.health.gov.il
Objectives:
To determine if there is added value to oncology studies performed with a dedicated in-line positron emission tomography (PET)/computed tomography (CT) scanner as compared with PET read side by side with diagnostic CT (DCT).
Methods:
Forty-one consecutive oncology patients referred for PET/CT who had contemporary DCT scans for review were enrolled. Body regions assessed on a DCT scan were assessed on PET/CT and by side-by-side reading of PET and DCT (SBS PET/DCT). Lesions identified on DCT, the CT portion of PET/CT, SBS PET/DCT, and the reading of fused PET/CT images were scored as benign or malignant. The PET portion of the PET/CT study was read by 2 teams: the first read the SBS PET/DCT scan and the other read the complete fused PET/CT scan. For discordant lesions, the final diagnosis was determined by pathologic findings (n = 6) or imaging follow-up (n = 21).
Results:
Twenty-seven (16.1%) of the 168 lesions were discordant when comparing analysis of fused PET/CT and SBS PET/DCT. Sixteen (9.5%) were fundamentally discordant, and 11(6.6%) were discordant in degree of confidence. For all discordant lesions only, the sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for PET/CT were 100%, 33%, 100%, 94%, and 78%, respectively, and for SBS PET/DCT, they were 38%, 50%, 19%, 73%, and 30%, respectively (P < 0.001 for sensitivity, P = not specific for specificity). The 2 main causes for misclassification on SBS PET/DCT were incorrect localization (n = 12) and changes occurring in the time gap between DCT and PET/CT (n = 4).
Conclusions:
In-line PET/CT offers better lesion localization in comparison to the visual fusion of PET and CT, especially for small lymph nodes, lesions adjacent to mobile organs, or lesions adjacent to the chest or abdominal wall.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...