Toward single-calibrant quantification in HPLC. A comparison of three detection strategies: evaporative light
Steve Lane1, Bob Boughtflower, Ian Mutton
1Analytical Sciences, CASS, Analytical Sciences, Chemical Development, GlaxoSmithKline, Gunnels Wood Road, Stevenage SG1 2NY, UK.
Abstract:
There is an urgent need for detection technologies that enable accurate and precise quantification of solutions containing small organic molecules in a manner that is rapid, cheap, non-labor-intensive, readily automated, and without a requirement for specific analyte standards. We provide a theoretical analysis that predicts that the logarithmic nature of the working domain of the evaporative light-scattering detector (ELSD) will normally bias toward underestimation of chromatographically resolved impurities, resulting in an overestimation of analyte purity. This analysis is confirmed by experiments with flow injection analysis (FIA) and gradient reversed-phase high performance liquid chromatography (RP-HPLC). Quantification is further compromised by the dependence of response parameters on the matrix composition and hence on the retention time of the analyte. Attempts were made to ameliorate these problems by using the response surface of a single compound to calibrate throughout the HPLC gradient. A chemiluminescent nitrogen detector (CLND) was also used in a similar manner, and the performance of the two techniques were compared against those of each other and that of a reference standard technique. A protocol for this purpose was developed using proton nuclear magnetic resonance (1H NMR) and the ERETIC method to enable quantification by integrating proton signals. The double-blind comparison exercise confirmed molar nitrogen CLND response to be sufficiently stable and robust across a methanol gradient to be used with a single external nitrogenous calibrant to quantify nitrogen-containing compounds of known molecular formula. The performance of HPLC-CLND was very similar to that of NMR, while that of HPLC-ELSD was seen to be significantly worse, showing it to be unsuitable for the purpose of single-calibrant quantification. We report details and experience of our use of RP-HPLC-CLND-MS to characterize and quantify small amounts of solutions of novel compounds at nominal levels of 10mM in microtiter plate (MTP) format.
Related Concept Videos
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
High-Performance Liquid Chromatography: Types of Detectors
2D NMR: Overview of Heteronuclear Correlation Techniques
Gas Chromatography: Types of Detectors-II
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...