Related Experiment Video
Updated: Aug 17, 2026

Aerobic Biodegradation Testing of Materials Using a Natural Marine Seawater Inoculum and Closed Loop Respirometer
Published on: October 24, 2025
Validation of respirometry as a short-term method to assess the efficacy of biocides
M Simões1, M O Pereira, M J Vieira
1Centro de Engenharia Biológica, Universidade do Minho, Braga, Portugal.
Abstract:
This study shows that a short-term respirometric measurement based on the rate of oxygen uptake needed to oxidize glucose is a reliable and fast method to assess biocide efficacy against P. fluorescens cells. Respiratory activity using oxygen consumption rate, the determination of viable and nonviable cells using Live/Dead BacLight kit and colony formation units (CFU), were compared as indicators of the biocidal efficacy of ortho-phthalaldehyde (OPA). The results showed that determining the effect of OPA against P. fluorescens using the different methods leads to different conclusions. The minimum bactericidal concentration (MBC) was 80 mgl(-1), 100 mgl(-1) and 65 mgl(-1) respectively, using respiratory activity, viability using BacLight counts and culturability. The plate count method was shown to underestimate the biocidal action of OPA, whilst data from respirometry and viability using Live/Dead BacLight kit correlated strongly and were not statistically different when yellow cells were considered nonviable. Respirometry therefore represents an expeditious, non-destructive and accurate method to determine the antimicrobial action of biocides against aerobic heterotrophic bacteria.