On estimation of the temperature maximum in intraluminal or intracavitary hyperthermia
H P Kok1, P M A van Haaren, J D P van Dijk
1Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, The Netherlands. h.p.kok@amc.uva.nl
Abstract:
During intraluminal or intracavitary hyperthermia treatments, limited non-invasive temperature information is available, which may result in sub-optimal treatment control. This article describes a method for estimating temperature maximums and their corresponding locations in tissue heated by a cylindrical applicator with an incorporated cooling system, assuming a hollow cylinder of homogeneous tissue. The main purpose of this study is intraluminal heating of tumours at the oesophagus, but the principle described is generally applicable for cylindrical applicators. When assuming no perfusion and only radial heat flow in the heated tissue, an analytical expression for the temperature profile can be derived such that the complete profile can be reconstructed from the inner wall temperature only. For situations with perfusion, finite difference simulations have been performed and the resulting simulated inner wall temperature was put into the analytical expression to obtain an estimation for the maximum temperature and the corresponding location. This way, an estimation method was developed which does not require a priori knowledge of the perfusion rate or invasive thermometry. For volumetric perfusion rates in the clinically relevant range of 0-10 kg m-3 s-1, the deviations between simulated and estimated temperature maximums were less than 10% and the difference in location was typically a few tenths of a millimetre. These deviations are small enough for treatment control purposes.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Body Temperature
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...