Related Experiment Video
Updated: Jun 12, 2026

Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Evaluation of a modified scavenging system to reduce occupational exposure to nitrous oxide in labor and delivery
Ed Chessor1, Marieke Verhoeven, Chun-Yip Hon
1School of Occupational and Environmental Hygiene, University of British Columbia, Vancouver, British Columbia, Canada. echessor@interchange.ubc.ca
We developed a new scavenging mask for the administration of nitrous oxide to mothers-to-be during labor in order to minimize leakage of the patient's exhaled breath into the room and, therefore, decreasing staff exposure to nitrous oxide. The scavenging system was designed with an inner mask for gas delivery, an outer mask to capture exhaled breath, and a continuous exhaust airflow based on breathing flow rates. In this study we field tested the scavenging system by measuring personal exposures of nurses (N = 30) and room air concentrations (N = 33), while patients self-administered nitrous oxide either through the conventional or modified scavenging system. Personal exposures were measured using passive nitrous oxide monitors, and area measurements were made using a direct-reading infrared analyzer. Information about volumes of nitrous oxide used, nurses' movements, and patients' use of the analgesic was recorded in order to examine factors that influenced exposures and the effectiveness of the scavenging system. The new scavenging system significantly reduced exposures in the room and to nurses (arithmetic mean nitrous oxide concentrations = 39.7 ppm and 40.2 ppm, respectively, compared with 82.2 ppm and 69.3 ppm, respectively, for the conventional system). Other factors associated with lower concentrations included larger distances between the nurse and the patient, and greater times since nitrous oxide was used. Observations during the field trial indicated that subjects did not hold the scavenging mask close enough to the face to capture exhaled breath during much of the time when the breath was highly contaminated. Additional modifications to the scavenging system are required to further reduce nitrous oxide concentrations and to improve comfort and usability.
We developed a new scavenging mask for the administration of nitrous oxide to mothers-to-be during labor in order to minimize leakage of the patient's exhaled breath into the room and, therefore, decreasing staff exposure to nitrous oxide. The scavenging system was designed with an inner mask for gas delivery, an outer mask to capture exhaled breath, and a continuous exhaust airflow based on breathing flow rates. In this study we field tested the scavenging system by measuring personal exposures of nurses (N = 30) and room air concentrations (N = 33), while patients self-administered nitrous oxide either through the conventional or modified scavenging system. Personal exposures were measured using passive nitrous oxide monitors, and area measurements were made using a direct-reading infrared analyzer. Information about volumes of nitrous oxide used, nurses' movements, and patients' use of the analgesic was recorded in order to examine factors that influenced exposures and the effectiveness of the scavenging system. The new scavenging system significantly reduced exposures in the room and to nurses (arithmetic mean nitrous oxide concentrations = 39.7 ppm and 40.2 ppm, respectively, compared with 82.2 ppm and 69.3 ppm, respectively, for the conventional system). Other factors associated with lower concentrations included larger distances between the nurse and the patient, and greater times since nitrous oxide was used. Observations during the field trial indicated that subjects did not hold the scavenging mask close enough to the face to capture exhaled breath during much of the time when the breath was highly contaminated. Additional modifications to the scavenging system are required to further reduce nitrous oxide concentrations and to improve comfort and usability.
More Related Videos
05:07Development of a Nose-only Inhalation Toxicity Test Chamber That Provides Four Exposure Concentrations of Nano-sized Particles
Published on: March 18, 2019
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Inhalational Anesthetics: Overview
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: