Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 19, 2026

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

A model for laminar diffusion-based complex electrokinetic passive micromixers.

Yi Wang1, Qiao Lin, Tamal Mukherjee

  • 1Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213, USA.

Lab on a Chip
|July 20, 2005
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Aptameric Metal-Organic Framework Nanobiosensor.

ACS applied nano materials·2026
Same author

Electroacupuncture Protects Against Post-MI Heart Failure Through Autonomic Regulation and α7nAChR Activation.

Cardiology research and practice·2026
Same author

Optimisation and validation of capture mNGS for predicting antimicrobial resistance.

EBioMedicine·2026
Same author

Author Correction: RIP-PEN-seq identifies a class of kink-turn RNAs as splicing regulators.

Nature biotechnology·2026
Same author

Cobalt-Catalyzed Asymmetric Cyclopropanation of Heteroaryl Alkenes with Homogeneous Zinc Carbenoids.

Journal of the American Chemical Society·2026
Same author

Design, Synthesis, and Evaluation of a Novel-Labeled Small Molecule Inhibitor-Based PET/SPECT Tracer Targeting HSP90.

Journal of medicinal chemistry·2026
Same journal

Microfluidic rare cell analysis beyond counting: workflow design from enrichment to multi-omics.

Lab on a chip·2026
Same journal

A sperm racetrack to separate sperm by swim speed.

Lab on a chip·2026
Same journal

Controlled encapsulation and droplet size prediction in two-step microfluidic double emulsions.

Lab on a chip·2026
Same journal

A particulate blood-mimicking fluid with physiological biconcave geometry for microscale hemorheology.

Lab on a chip·2026
Same journal

Multicellular sensor arrays fabricated by capillary stamping for pattern-based odor discrimination.

Lab on a chip·2026
Same journal

A real-time microfluidic surveillance system for multiplex detection of heavy metal contamination in wastewater.

Lab on a chip·2026
See all related articles

This study introduces a new model for simulating electrokinetic passive micromixers, improving computational efficiency for complex designs. The model accurately predicts mixing performance, aiding in the development of advanced microfluidic devices.

Area of Science:

  • Microfluidics
  • Computational Science
  • Electrokinetics

Background:

  • Simulating complex electrokinetic passive micromixers is computationally intensive.
  • Existing models may lack efficiency for intricate designs.

Purpose of the Study:

  • To develop an efficient and accurate model for simulating laminar diffusion-based complex electrokinetic passive micromixers.
  • To represent complex micromixers as systems of simpler geometric elements.

Main Methods:

  • Developing parameterized and analytical models for individual mixing elements.
  • Constructing a lumped-parameter and system-level model using these element models.
  • Ensuring parameter continuity at interfaces between adjacent elements.

Main Results:

More Related Videos

Microfluidic Mixers for Studying Protein Folding
12:42

Microfluidic Mixers for Studying Protein Folding

Published on: April 10, 2012

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
10:12

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique

Published on: June 12, 2015

Related Experiment Videos

Last Updated: Jun 19, 2026

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

Microfluidic Mixers for Studying Protein Folding
12:42

Microfluidic Mixers for Studying Protein Folding

Published on: April 10, 2012

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
10:12

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique

Published on: June 12, 2015

  • The system-level model accurately computes electric circuitry and sample concentration distributions.
  • The model achieves orders-of-magnitude improvement in computational efficiency compared to full simulations.
  • The model's effectiveness is demonstrated on various practical micromixer designs.

Conclusions:

  • The developed model offers a computationally efficient and accurate approach for simulating complex electrokinetic passive micromixers.
  • This method facilitates the exploration and optimization of micromixing networks.
  • The model provides a valuable tool for advancing microfluidic device design and application.