Related Experiment Video
Updated: Aug 16, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays
Frank Verhaegen1, Brigitte Reniers, François Deblois
1Medical Physics Department, McGill University Health Centre, Montreal General Hospital, 1650 Cedar Avenue, Montreal, Québec, H3G 1A4, Canada. fverhaegen@medphys.mcgill.ca
Abstract:
Kilovolt x-rays are clearly suboptimal compared to MV photon beams for radiotherapy of deep-seated tumours because of the increased attenuation in tissue, causing a rapid dose fall-off. This picture could change drastically when tumours can be labelled with contrast medium, containing high atomic number elements. This causes a significant dose enhancement to the tumour by exploiting the high cross sections for the photo-electric effect for kV x-rays. In this work, we have investigated the dosimetric and microdosimetric characteristics of kV contrast-enhanced radiation therapy (CERT) for different photon energies, contrast-medium concentrations and types (I and Gd). Two idealized patient treatment plans (head and lung) for irradiation with CT-arc beams were calculated. It is shown that the dose enhancement in tumours can be highly significant (up to about sixfold for realistic 80-120 kVp x-ray spectra and an iodine concentration of 50 mg ml-1) but that dose homogeneity in the tumour depends on photon energy, contrast-medium concentration and type, and irradiation scheme. An attempt to optimize the irradiation scheme is discussed. The microdosimetric study of the dose mean lineal energy shows that radiation quality changes in the contrast-medium-labelled region compared to homogeneous tissue are fairly small and limited to 10%. It is concluded that kV-CERT is a promising radiotherapy technique, provided contrast medium can be delivered reliably to tumours.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Biological Effects of Radiation