Related Experiment Video
Updated: Aug 16, 2026

The Flexible Rhino-Laryngoscope for Awake Nasotracheal Intubation
Published on: August 2, 2024
Open endotracheal tubes may be safely left on an ED airway cart for 48 hours
W Douglas Browder1, Marcus P Cromer, Francis L Counselman
1Department of Emergency Medicine, Eastern Virginia Medical School and Emergency Physicians of Tidewater, Norfolk, VA 23507, USA.
Objective:
To determine if endotracheal tubes (ETTs) that are opened, prepared, and stored in an ED airway cart are prone to bacterial contamination.
Methods:
A prospective study conducted in the ED of a level 1 trauma center. A study group of 50 endotracheal tubes were opened, preloaded with a stylet, the cuff checked for integrity by air inflation, and then stored in an ED airway cart. The study group was subdivided into 5 groups of 10 ETTs each, cultured at different time intervals. The ETTs were cultured at 6, 12, 24, 36, and 48 hours for the presence of bacterial contamination. The control group consisted of 10 ETTs that were left in their sterile packing in the ED airway cart and then removed at 48 hours and cultured.
Results:
In the study group, 7 (14%) ETTs resulted in a positive culture; 43 ETTs cultured negative for bacteria. In the control group, 2 (20%) ETTs cultured positive, the remainder was all negative. There was no statistically significant difference between the 2 groups (P = .63). If only clinically significant bacteria are considered, defined as a culture with 5 or more colony-forming units, 3 ETTs in the study group cultured positive; there were no clinically significant bacteria cultured in the control group. Once again, there was no statistically significant difference between the 2 groups, with a P value of .57.
Conclusion:
It appears that opening, preparing, and storing ETTs in an ED airway cart for up to 48 hours does not increase the risk of bacterial contamination of the ETTs.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...