Related Experiment Video
Updated: Aug 15, 2026

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Varying the heart rate response to dynamic exercise in pacemaker-dependent subjects: effects on cardiac output and
Lysander W J Bogert1, Ayten Erol-Yilmaz, Raymond Tukkie
1Department of Internal Medicine, Academic Medical Centre, University of Amsterdam, 1100 DE Amsterdam, The Netherlands.
Abstract:
Cerebral blood flow increases upon the transition from rest to moderate exercise, but becomes affected when the ability to raise CO (cardiac output) is limited. HR (heart rate) is considered to contribute significantly to the increase in CO in the early stages of dynamic exercise. The aim of the present study was to test whether manipulation of the HR response in patients dependent on permanent rate-responsive ventricular pacing contributes to the increase in CO, MCA V(mean) [mean MCA (middle cerebral artery) velocity] and work capacity during exercise. The effect of setting the pacemaker to DSS ('default' sensor setting) compared with OSS ('optimized' sensor setting) on blood pressure, CO, SV (stroke volume) and MCA V(mean) was evaluated during ergometry cycling. From rest to exercise at 75 W, the rise in HR in OSS [from 73 (65-87) to 116 (73-152) beats/min; P<0.05] compared with DSS [70 (60-76) to 97 (67-117) beats/min; P<0.05] was larger. There was an increase in SV during exercise with DSS, but not with OSS, such that, at all workloads, SVs were greater during DSS than OSS. The slope of the HR-CO relationship was larger with DSS than OSS (P<0.05). From rest to exercise, MCA V(sys) (systolic MCA velocity) increased in OSS and DSS, and MCA V(dias) (diastolic MCA velocity) was reduced with DSS. No changes were observed in MCA V(mean). Manipulation of the pacemaker setting had no effect on the maximal workload [133 (100-225) W in OSS compared with 129 (75-200) W in DSS]. The results indicate that, in pacemaker-dependent subjects with complete heart block and preserved myocardial function, enhancing the HR response to exercise neither augments CO by a proportional offset of the exercise-induced increase in SV nor improves cerebral perfusion.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
07:49A Pacing-Controlled Procedure for the Assessment of Heart Rate-Dependent Diastolic Functions in Murine Heart Failure Models
Published on: July 21, 2023
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Pathophysiology of Cardiac Performance
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...