Dynamic effects of joint-leveling procedure on pressure at the distal radioulnar joint
Toshiki Miura1, Keikhosrow Firoozbakhsh, Tahseen Cheema
1Department of Orthopaedics and Rehabilitation, School of Medicine, University of New Mexico, Albuquerque, NM 87131-0001, USA.
Purpose:
Wrist joint-leveling procedures for decompression of the radiocarpal and ulnocarpal joints are accompanied by the risk for subsequent disorders of the adjacent distal radioulnar joint (DRUJ). This study evaluated the dynamic change of the pressure pattern at the DRUJ after joint-leveling procedures.
Methods:
Thirteen fresh-frozen adult cadaveric upper extremities were used. A segment of the radius was excised at its midshaft to allow lengthening and shortening via a mini external fixator attachment. Dynamic pressure sensors were inserted into the DRUJ and the ulnocarpal joint. Axial loads were applied to the extensor carpi radialis brevis, extensor carpi radialis longus, extensor carpi ulnaris, flexor carpi radialis, and flexor carpi ulnaris for a total of 89 N with or without 30 N of radioulnar loading. The dynamic pressure distribution for full range of forearm rotation was recorded from 6 mm of radial shortening to 6 mm of radial lengthening in increments of 1 mm.
Results:
The peak pressures at the DRUJ before the joint-leveling procedures averaged 3.3 MPa without radioulnar loading and 5.0 MPa with radioulnar loading. The peak pressures with axial and radioulnar loading increased 85% at 6 mm of lengthening and only 8% at 6 mm of shortening. The peak pressures at the DRUJ for radial lengthening of 4 mm or more were significantly greater than that of the original length. Pressure at the ulnocarpal joint increased in proportion to the amount of radial shortening and decreased with radial lengthening.
Conclusions:
Radial lengthening but not radial shortening significantly increases the peak pressure at the DRUJ.
Related Concept Videos
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in pressure...
Bones of the Upper Limb: Ulna
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Normal Strain under Axial Loading