Related Experiment Video
Updated: Aug 10, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Infrared thermography to mass-screen suspected SARS patients with fever
1Department of Neurosurgery, Taipei Medical University, Wan Fang Hospital. hychiou@tmu.edu.tw
Abstract:
Fever greater than 38 degrees C is a cardinal sign of patients with the severe acute respiratory syndromes (SARS). To reduce the risk of nosocomial cross infections, screening all patients and visitors who visit hospitals and clinics for fever at the entrance of every hospital building has become a standard protocol in Taiwan during the SARS epidemic from mid-April to mid-June 2003. We used a digital infrared thermal imaging (DITI) system (Telesis Spectrum 9000 MB) to conduct mass screening of patients and visitors who entered the hospital to identify those with fever. The DITI system has two components: a sensor head and a PC imaging workstation. The sensor head is an optic-mechanical device which consists of imagining optics for focusing the infrared source information on the infrared detector. The infrared images are further converted into electrical signals, which are then processed for real-time display on the monitor. During the period from April 13 to May 12 2003, 72,327 outpatients and visitors entered Taipei Medical University-Wan Fang Hospital, Taipei, Taiwan. A total of 305 febrile patients (0.42%) was detected by infrared thermography. Among them, three probable SARS patients were identified after thorough studies including contact history, laboratory tests and radiology examinations. The findings suggests that infrared thermography was an effective and reliable tool ideal for mass-screening patients with fever in the initial phase of screening for SARS patients at a busy hospital which sees approximately 3,000 outpatients every weekday during the SARS epidemic.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...