Permeation risks with peracetic acid and hydrogen peroxide sterilizing agent inside ambulatory pumps
Celine Bourguignon1, Bourguignon Celine, Amandine Grain
1Department of Pharmacy and Toxicology, University Hospital of Jean Verdier, Avenue du 14 juillet, 93140 Bondy, France.
Abstract:
The sterilizing agent commonly used to sterilize materials for an isolator is a peracetic acid (PA) and hydrogen peroxide (HP) mixture. The permeation of this agent through ambulatory pumps should reveal a potential toxic risk for the patient and a stability modification of the drug by a pH change. Six wrapped and six unwrapped ambulatory pumps from each laboratory were introduced in the transfer chamber for the sterilizing process over 2 h 45 min. The presence of PA and HP were determined by using analytical strips. If the analytical strips of HP were positive, the level of HP was determined by using a specific spectrometric kit. No acid permeation was found in all wrapped pumps. Acid permeation was found in two samples of Ultraflow unwrapped series and in one unwrapped sample of Easypump series by the analytical strips. In other unwrapped samples, no acid permeation was detected. In four unwrapped ambulatory pumps (Accufuser, Infusor, Ultraflow, and Easypump), the analytical strips of HP were positive in the range of 0.5 to 25 mg/L, varying by laboratory. In only one sample (Surefuser), no detection of HP was found. The quantitative dosage of HP by spectrophotometry confirmed the permeation risk inside all pumps except the Surefuser. Our investigation shows that the permeation risk inside ambulatory pumps is real when pumps are unwrapped and exposed at high levels to PA and HP mixture. The results of our study recommend retaining the wrapping for the peracetic acid sterilization of the ambulatory pumps.
More Related Videos
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Chemical Agents for Microbial Control