Identification of schizophrenic patients by examination of body odor using gas chromatography-mass spectrometry and a cross-selective gas sensor array
Related Experiment Video
Updated: Aug 16, 2026

Identification of Olfactory Volatiles using Gas Chromatography-Multi-unit Recordings (GCMR) in the Insect Antennal Lobe
Published on: February 24, 2013
Corrado Di Natale1, Roberto Paolesse, Giuseppe D'Arcangelo
1Department of Electronic Engineering, University of Rome Tor Vergata, Rome, Italy CNR-IMM, Rome, Italy. dinatale@uniroma2.it
Background:
Previous findings have shown that the body odor of patients affected by schizophrenia contains some specific compounds. Chemical sensor technology has proved to be able to classify different odours. We investigated the possibility of using a chemical sensor array to detect body odor alteration in schizophrenic patients.
Material/Methods:
The sweat of subjects was sampled and analysed by Gas Chromatography-Mass Spectrometry (GC-MS) and by an array of cross-selective gas sensors. A total of 27 individuals were involved in the experiment: 9 schizophrenics, 9 with other mental disorders, and 9 controls.
Results:
GC-MS analysis showed a richer composition for the sweat of schizophrenic patients. Nevertheless, the individuation of specific markers was unsuccessful. On the other hand, statistical analysis of cross-selective gas sensor data provided a complete classification of schizophrenic patients with respect to the other three groups.
Conclusions:
The alteration of body odor in schizophrenic patients was confirmed by GC-MS and chemical sensor array. Results show that the alteration is complex and cannot be limited to a single compound, but rather to a global variation of the body odor.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Types of Detectors