Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
[Characteristic of evaluation of new image filter devised for improvement of workflow in CT examination]
Takanori Hara1, Katsuhiro Ichikawa, Masatoshi Tsuzaka
1Department of Radiology, Nakatsugawa Municipal General Hospital.
Abstract:
In this study, we processed reconstructed images with a new image filter (Siemens Medical Systems, Adaptive Image Filter: AIF). As one of its characteristics, the filter uses low-pass filtering. When an image that emphasizes a high-frequency element is changed to one with a reduced high-frequency element, an image suitable for clinical use can be obtained. For the resolving characteristic and the noise characteristic, we evaluated the degree of transition, using the modulation transfer factor (MTF) and Wiener spectrum (WS). Moreover, we used the signal-to-noise ratio (SNR) to examine the total loss of signal detection capability after use of the AIF. The results showed that, when we changed to images using the AIF and made it the same level as B30 and U40, we had to hold down the kernel level to at least B60 and U80. The use of an image filter did not recognize less of an SNR in comparison with the reconstruction image. In this study, changes in detailed characteristics of the image and SNR could be evaluated objectively using the AIF. As for the effective method by AIF that raw data isn't used for is available for the control of an image (times) using reconstruction and the change of an image on database. Therefore, we consider the AIF useful to improve workflow in CT examinations.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...