On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Monitoring industrial wastewater by online GC-MS with direct aqueous injection
M Wortberg1, W Ziemer, M Kugel
1BASF Aktiengesellschaft, Environmental Analytics, 67056 Ludwigshafen, Germany. monika.wortberg@basf-ag.de
Abstract:
An online GC-MS-system for automated monitoring of crude wastewater at a complex chemical production site is presented. The modular system is, in principal, based on commercial equipment, but utilizes a special, two-stage injector, which consists of a splitless vaporization chamber on top of a PTV injector filled with Tenax. This set-up enables direct injection of wastewater. Almost 140 volatile and semi-volatile compounds are calibrated down to 1 mg L(-1), which is sufficient for analysis of the influent of the wastewater-treatment plant. Two instruments analyze alternately, every 20 min, and the instrument cycle time is 40 min. The quantitative results are transferred to a database which is connected to a process-control system. Depending on the nature and concentration of a compound, an alarm can be generated and the wastewater stream can be diverted into an "off spec tank" if necessary. The GC-MS-system operates quasi-continuously with a system availability >98%. Data quality is automatically controlled in each run and by daily analysis of a quality-control sample. The development of a novel stacked PTV-PTV injector design to expand the range of analytes to selected basic compounds is described.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.