Related Experiment Video
Updated: Aug 16, 2026

Electrochemical Preparation of Poly(3,4-Ethylenedioxythiophene) Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Electro-deposit polyaniline on carbon electrode for voltammetric detection of lipase
Arun Kumar1, Graham Whitaker, Ashok Kumar
1Nanomaterial and Nanomanufacturing Research Center and Department of Mechanical Engineering, University of South Florida, Tampa, FL, USA.
Abstract:
Normally, the pancreatic digestive enzymes are created and carried into the duodenum in an inactive form. During pancreatitis attacks, these enzymes are inhibited from reaching the duodenum, become activated while still in the pancreas, and begin to autodigest and destroy the pancreas. In order to accurately detect lipase within seconds, a square wave technique was explored without immobilizing enzyme and any other biomolecules over the electrode surface. The cyclic voltammetric (CV) technique was used to coat a carbon electrode with a thin layer of polyaniline. This modified electrode proved to be highly sensitive and specific to detect lipase between 0 and 225 IU/L, which is well within the normal physiological range. The consistency and reliability of this technique proved to be a very formidable detector of lipase present in abnormal quantities due to pancreatitis and other pathological disorders. The interference test has been performed to detect the lipase in the presence of amylase 50, 100, and 150 IU/L to understand the interference phenomenon with lipase detection. There is no significant effect of the amylase concentration over lipase detection resulting from using a modified carbon electrode. The response time of the modified carbon electrode is approximately 5s and the electrode has shown to be stable for 4 weeks at room temperature without special storage condition.
More Related Videos
Related Concept Videos
Electrodeposition
Electrodeposition can...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...

