Training and calibration improve inter-reader reliability of joint damage assessment using magnetic resonance image

Paul Bird1, Fredrick Joshua, Marissa Lassere

  • 1Rheumatology Department and the Magnetic Resonance Imaging Department, St. George Hospital, Kogarah, New South Wales, Australia. birdp@sesahs.nsw.gov.au

Abstract

Insights

Training significantly improved inter-reader reliability for rheumatoid arthritis MRI assessments in wrist joints. However, erosion volume measurement reliability in metacarpophalangeal joints remained limited due to technical challenges.

Area of Science:

  • Rheumatology
  • Radiology
  • Medical Imaging Analysis

Background:

  • Rheumatoid arthritis (RA) assessment often relies on imaging to detect joint damage.
  • Standardizing interpretation of magnetic resonance imaging (MRI) for RA is crucial for reliable disease monitoring.

Purpose of the Study:

  • To evaluate the inter-reader reliability of two MRI assessment methods for rheumatoid arthritis (RA) joint erosion.
  • To compare reliability before and after standardized training for rheumatologist readers.

Main Methods:

  • Two reader groups assessed erosion volumes and OMERACT-5 Rheumatoid Arthritis MRI Score (OM-5 RAMRIS) in wrist and metacarpophalangeal (MCP) joints.
  • Assessments were performed before and after a 3-hour training session and calibration sessions.
  • Inter-reader agreement was quantified using intraclass correlation coefficients (ICC).

Main Results:

  • For wrist joints, inter-reader agreement significantly improved post-training for both volume (ICC 0.21 to 0.92) and scoring (ICC 0.46 to 0.85) methods.
  • Metacarpophalangeal (MCP) joint erosion volume assessment showed limited improvement post-training (ICC 0.51 to 0.58).
  • Scoring in MCP joints showed moderate improvement (ICC 0.61 to 0.75).

Conclusions:

  • Inter-reader agreement for MRI-based RA joint assessment is higher in wrist joints compared to MCP joints.
  • Difficulties in manual outlining of erosion borders in MCP joints limit the reliability of erosion volume measurements.
  • Standardized training enhances the reliability of MRI scoring and volume assessment, particularly for wrist joints.