Related Experiment Video
Updated: Aug 10, 2026

Microfluidic Flow Chambers Using Reconstituted Blood to Model Hemostasis and Platelet Transfusion In Vitro
Published on: March 19, 2016
Hemolysis during percutaneous mechanical thrombectomy can mimic a hemolytic transfusion reaction
D C Mair1, T Eastlund, G Rosen
1Division of Transfusion Medicine, Department of Laboratory Medicine and Pathology, University of Minnesota Medical School, Minneapolis, Minnesota, USA. maird@usa.redcross.org
Background:
Interventional radiologists have developed percutaneous mechanical thrombectomy (PMT) devices to remove intravascular thrombi. Hemolysis, secondary to thrombus destruction from these devices, has been described in radiology journals, but similar reports appear to be lacking in the transfusion medicine literature. Two cases of hemolysis after PMT are described that involved the transfusion service, one of which was reported as a hemolytic transfusion reaction.
Case Reports:
The first patient received 4 units of red cells (RBCs) during a thrombectomy and subsequent placement of a transjugular intrahepatic portosystemic shunt. The patient developed hemoglobinuria, and it was reported to the blood bank as a possible hemolytic transfusion reaction. After RBC mismatch and bacterial contamination were excluded, the hemolysis was attributed to thrombectomy-related mechanical hemolysis. In the second case, a hemolyzed sample was sent to the blood bank for a type and cross-match. Upon requesting that the sample be redrawn, it was learned that the sample was obtained after PMT.
Conclusion:
Patients who have undergone PMT can have clinical and laboratory findings suggestive of hemolytic transfusion reactions. Although interventional radiologists are familiar with these side effects, the blood bank profession needs to be aware that these procedures cause nonimmune hemolysis and must consider this possibility when evaluating transfusion reactions in these patients.
More Related Videos
05:23Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
09:38A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Introduction to Hemostasis
The three phases of hemostasis involve many clotting factors present in plasma and several substances released by platelets and injured tissue cells. It is a fast, localized, and...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Hemorrhagic Stroke ll: Pathophysiology