Related Experiment Video
Updated: Aug 16, 2026

Biosensor for Detection of Antibiotic Resistant Staphylococcus Bacteria
Published on: May 8, 2013
Methicillin-resistant Staphylococcus aureus: comparison of susceptibility test methods with mecA gene analysis for
Z Cekovska1, N Panovski, M Petrovska
1Institute for Microbiology and Parasitology, Medical Faculty, Skopje, Republic of Macedonia. z.cekovska@yahoo.com
Abstract:
The aim of the study was to determine which of the following susceptibility test methods, using recommended or modified NCCLS, best detects oxacillin resistance: disk diffusion, agar screen, and broth dilution. PCR for mecA was used as "gold standard". We studied 120 Staphylococcus aureus isolates received from different patients hospitalized at the Clinical center in Skopje from May 2001 to November 2003. There were no two isolates from the same patient. Methicillin resistance in Staphylococcus aureus strains was performed according to the recommendations of the National Committee for Clinical Laboratory Standards (NCCLS). PCR appears to be promising. Since variations among the methods exist and no acceptable guidelines are formulated, a combination of conventional methods, including either 3 microg of oxacillin/ml. in Mueller Hinton broth or one of the screen agar plates (6 microg/ml), alone or with PCR should be the method of choice for the detection of MRSA. (Tab. 4, Ref. 12.)
Related Concept Videos
Clinical Significance of Antibiotic Resistance
Mechanism of Antibiotic Resistance in MRSA