Related Experiment Video
Updated: Aug 16, 2026

Early Weight-Bearing Rehabilitation Protocol After Anterior Cruciate Ligament Reconstruction
Published on: March 1, 2024
Primary stability of three posterior cruciate ligament reconstruction procedures: a biomechanical in vitro study
Nobuto Kitamura1, Kazunori Yasuda, Harukazu Tohyama
1Department of Sports Medicine and Joint Reconstruction Surgery, Hokkaido University School of Medicine, Sapporo, Japan.
Purpose:
Posterior cruciate ligament (PCL) reconstruction procedures have not been thoroughly evaluated under cyclic loading conditions. We tested the hypothesis that PCL reconstruction with a quadrupled flexor-tendon graft and fixation using tapes and staples is biomechanically superior to that fixed with sutures, a button, and a post-screw, and is comparable to reconstruction with a bone--patellar tendon--bone (BPTB) graft.
Study Design:
In vitro biomechanical study.
Methods:
A total of 45 porcine knees were used. The quadrupled flexor-tendon graft was fixed using the suture/button/post-screw procedure in 15 knees, and with the tape/staples procedure in another 15 knees. The remaining 15 knees underwent reconstruction with a BPTB graft secured with screws as the standard control. In each group of 15 knees, 5 underwent tensile testing without cyclic loading, and 10 underwent the same tensile test after 5,000 cycles of load-controlled or displacement-controlled loading.
Results:
Each type of cyclic loading produced larger biomechanical changes in the knees fixed with the suture/button/post-screw procedure than in the knees secured using the other 2 procedures.
Conclusions:
In PCL reconstruction, the tape/staples procedure is biomechanically superior to the suture/button/post-screw procedure, and is comparable to the BPTB/screws procedure with regard to the ultimate failure load. Neither of the procedures using the quadrupled flexor-tendon graft was comparable to the BPTB graft in linear stiffness and the initial displacement after load-controlled cyclic testing.
Clinical Relevance:
The biomechanical behaviors of PCL-reconstructed knees are significantly different, depending on surgical techniques.