Related Experiment Video
Updated: Aug 16, 2026

Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice
Published on: June 15, 2020
Right ventricular pressure-volume loops using simultaneous radionuclide angiography with a multiwire gamma camera and
Thein Htay1, Deval Mehta, Liang Sun
1Division of Cardiovascular Diseases, Department of Medicine, University of Alabama at Birmingham, 1900 University Boulevard, Birmingham, AL 35294, USA.
Background:
The purpose of this study was to generate right ventricular (RV) pressure-volume loops (PVLs) from time-activity curves obtained by first-pass radionuclide angiography (RNA) and RV pressures obtained by right heart catheterization.
Methods And Results:
Short-lived tantalum 178 was used to obtain first-pass RNA at baseline (n = 31), after nitroglycerin (n = 5), or after the conclusion of cardiac catheterization (n = 13). From the radionuclide-derived RV ejection fraction and thermodilution stroke volume, the RV end-diastolic volume and end-systolic volume were measured. Special proprietary software was developed and used to integrate the pressure and the RNA data. The mean heart rate was 80 +/- 17 beats/min; RV ejection fraction, 39% +/- 12%; RV end-diastolic volume, 217 +/- 79 mL; RV end-systolic volume, 142 +/- 74 mL; and RV end-diastolic pressure, 10 +/- 7 mm Hg. The RV PVLs were of high quality and reproducible.
Conclusions:
This study provides proof of concept of the feasibility of generating RV PVL; the short half-life (10 minutes) and low energy (59 keV) of Ta-178 allow the generation of multiple loops at low radiation exposure. Such studies could be performed at the bedside and provide a wealth of information that may have clinical and research merits.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...