Related Experiment Video
Updated: Aug 16, 2026

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Patterns of changes in arterial PO2 during one-lung ventilation: a comparison between patients with severe pulmonary
Schlomo V Aschkenasy1, Christoph K Hofer, Marco P Zalunardo
1Institute of Anesthesiology, University Hospital Zurich, 8063 Zurich, Switzerland.
Objectives:
One-lung ventilation (OLV) during thoracoscopic surgery is associated with a significant decline in arterial PO(2) in patients with severe pulmonary emphysema and patients with preserved lung function. The authors hypothesized that patterns of arterial PO(2) changes are different in these 2 patient groups.
Design:
Prospective nonrandomized study.
Setting:
University hospital.
Participants:
Twenty-five patients undergoing thoracoscopic interventions: 16 with severe pulmonary emphysema and 9 patients without emphysema.
Interventions:
Continuous arterial blood gas measurement (PaO(2), PaCO(2), pHa) during OLV of the left lung in left lateral position using the Paratrend 7 blood gas monitoring system (PT7; Pfizer Hospital Products Group, High Wycombe, UK).
Main Results:
The decrease of PaO(2) was delayed in patients with severe emphysema. Steady state (defined as DeltaPaO(2) <7.5 mmHg/min) was reached after 18 +/- 4 minutes compared with 11 +/- 3 minutes (mean +/- standard deviation) in patients with normal lung function (p = 0.0002). PaO(2) values at steady state were comparable (p = 0.49); the pattern of changes in PaO(2) for the first 15 minutes of left-sided OLV was significantly different between the groups (p = 0.0004). The difference of predicted versus measured PaO(2) at steady state was -48 +/- 160 mmHg for patients with emphysema and -51 +/- 60 mmHg for patients with normal lung function (p = 0.019).
Conclusion:
During OLV, oxygenation is better preserved for a longer period of time in patients with severe pulmonary emphysema as compared with patients with normal lung function. In contrast to patients without emphysema, prediction of oxygenation during OLV for the individual patient with emphysema is unreliable because of large interindividual differences.
More Related Videos
Related Concept Videos
Chronic Obstructive Pulmonary Disease II: Emphysema
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Atelectasis II: Pathophysiology
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Respiratory Volumes and Capacities I
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...