Effective systolic orifice area of the aortic valve: implications for Doppler echocardiographic cardiac output
C Schmidt1, G Theilmeier, H Van Aken
1Department of Anesthesiology and Surgical Intensive-Care Medicine, University of Münster Hospital, Münster, Germany. schmch@uni-muenster.de
Background:
Substantial research using echocardiography has established that stroke volume (SV) or cardiac output (CO) can be measured non-invasively at the level of the aortic valve (AV) with high accuracy. Stroke volume is the product of the velocity time integral occurring at the sampling site and the effective systolic AV orifice area (AVOAeff). Nevertheless, a generally accepted method for the determination of AVOAeff is still lacking.
Methods:
Aortic valve OAeff was measured in 228 consecutive patients scheduled for coronary artery surgery. Two widely adopted methods were applied to approximate the constantly changing orifice area of the AV: (1) the circular orifice model (AVOA-CM), and (2) the triangular orifice model (AVOA-TM). Aortic valve OA-CM assumes the shape of a circle as an appropriately time averaged geometrical model, and AVOA-TM takes the shape of an equilateral triangle for granted.
Results:
The AV was easily imaged by echocardiography in both short- and long-axis views in all patients. Relying on AVOA-CM, AVOAeff was 3.49+/-0.77 cm2. AVOA-TM estimates were 2.80+/-0.55 cm2 (mean+/-SD). The results did not agree (bias analysis).
Conclusions:
The echocardiographic measurement of SV or CO at the level of the AV has to be reconsidered.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...