High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Intra-individual variability of cardiac uptake on serial whole-body 18F-FDG PET
Amir H Khandani1, Carmen R Isasi, M Donald Blaufox
1Department of Nuclear Medicine, Montefiore Medical Center & Albert Einstein College of Medicine, New York, USA. khandani@med.unc.edu
Objective:
To measure the variability of cardiac uptake on serial whole-body F-FDG PET scans.
Methods:
Two hundred and eighteen whole-body PET scans were performed in 47 patients with different primary malignancies between October 1996 and April 2003 on a dedicated PET system. The number of scans per patient ranged between four and nine. Two experienced nuclear medicine physicians reviewed the scans retrospectively using the non-attenuation corrected images to assess the cardiac FDG uptake. Patients with cardiac uptake less or equal to lung uptake were assigned in the "low" uptake group, and those with cardiac uptake more than the lung uptake were assigned to the "high" uptake group. The reproducibility of cardiac uptake on serial whole-body PET scans and the effect of age, sex, weight, diabetes and primary diagnosis on cardiac uptake was evaluated.
Results:
There was very good reproducibility (intra-class correlation coefficient=0.77) of individual cardiac FDG uptake on serial whole-body PET scans. Diabetics (n=6) in comparison to non-diabetics were less likely to have high cardiac uptake (odds ratio (OR)=0.24, P<0.05). Patients with lymphoma (n=12) in comparison to patients with other primary diagnoses were more likely to have high cardiac uptake (OR=8.6, P<0.05). There was no association between cardiac uptake and age, sex or weight.
Conclusion:
Cardiac FDG uptake on whole-body PET does not appear to change significantly over time. It is likely that uptake is determined by individual characteristics; these likely include diabetes and primary diagnosis of lymphoma.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
15:10A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET