Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Ventricular catheter tack-down suture: technical note.

Eric C Leuthardt1, Michael R Chicoine, Robert L Grubb

  • 1Department of Neurosurgery, Washington University School of Medicine, and Alvin Siteman Cancer Center at Barnes-Jewish Hospital, Saint Louis, MO 63110, USA.

Surgical Neurology
|August 16, 2005
PubMed
Summary

A new technique rigidly fixes shunt tubing to the skull, significantly reducing complications from tubing migration and disconnection. This method enhances shunt reliability and patient outcomes.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pediatric Endoscopic Skull Base Surgery: Safety, Efficacy, and Lessons Learned.

Journal of neurological surgery. Part B, Skull base·2026
Same author

Right insular glioma in right-handed patient with bilateral language dominance: a multimodal guided awake craniotomy. Illustrative case.

Journal of neurosurgery. Case lessons·2026
Same author

Aperiodic and oscillatory activity of the human brain during induced emotional states.

medRxiv : the preprint server for health sciences·2026
Same author

Sonobiopsy for enrichment of circulating microRNAs in glioma patients.

Neuro-oncology advances·2026
Same author

Current Concepts in the Management of Cerebral Aneurysms.

Missouri medicine·2026
Same author

Comparison of clinical outcomes in adamantinomatous and papillary craniopharyngioma: a baseline analysis before the targeted therapy era.

Neurosurgical focus·2026

Area of Science:

  • Neurosurgery
  • Medical Device Engineering

Background:

  • Shunt tubing migration is a common complication leading to device failure.
  • Disconnection of shunt components can result in serious neurological issues.

Purpose of the Study:

  • To develop and evaluate a novel technique for rigidly fixing proximal shunt tubing to the skull.
  • To reduce the incidence of shunt disconnection and tubing migration.

Main Methods:

  • A surgical technique involving a twist drill hole adjacent to the catheter burr hole was developed.
  • A suture is passed through the twist drill hole to rigidly secure the proximal shunt tubing and valve to the skull.

Main Results:

  • The described method provides a secure fixation of the shunt components.

Related Experiment Videos

  • This technique effectively minimizes the risk of proximal shunt tubing migration.
  • Conclusions:

    • Rigid fixation of proximal shunt tubing to the skull is an effective method to prevent shunt complications.
    • This technique offers an efficient solution for improving shunt reliability and patient safety.