Related Experiment Video
Updated: Aug 12, 2026

05:46
Rapid Screening of HIV Reverse Transcriptase and Integrase Inhibitors
Published on: April 9, 2014
Filtration sizes of human immunodeficiency virus type 1 and surrogate viruses used to test barrier materials
C D Lytle1, S C Tondreau, W Truscott
1Food and Drug Administration Center for Devices and Radiological Health, Rockville, Maryland.
Applied and Environmental Microbiology
|February 1, 1992
Abstract:
Filters with well-defined holes were used to determine the effective diameters in buffer of human immunodeficiency virus type 1, herpes simplex virus type 1, and four bacteriophages (phi X174, T7, PRD1, and phi 6), which may serve as surrogate viruses for testing barrier materials. Bacteriophages phi 6 and PRD1 most closely model human immunodeficiency virus type 1 in filtration size.